Kernel driver bpa-rs600¶
Supported chips:
BPA-RS600-120
- Datasheet: Publicly available at the BluTek website
 http://blutekpower.com/wp-content/uploads/2019/01/BPA-RS600-120-07-19-2018.pdf
- Authors:
 Chris Packham <chris.packham@alliedtelesis.co.nz>
Description¶
The BPA-RS600 is a compact 600W removable power supply module.
Usage Notes¶
This driver does not probe for PMBus devices. You will have to instantiate devices explicitly.
Sysfs attributes¶
curr1_label  | 
“iin”  | 
curr1_input  | 
Measured input current  | 
curr1_max  | 
Maximum input current  | 
curr1_max_alarm  | 
Input current high alarm  | 
curr2_label  | 
“iout1”  | 
curr2_input  | 
Measured output current  | 
curr2_max  | 
Maximum output current  | 
curr2_max_alarm  | 
Output current high alarm  | 
fan1_input  | 
Measured fan speed  | 
fan1_alarm  | 
Fan warning  | 
fan1_fault  | 
Fan fault  | 
in1_label  | 
“vin”  | 
in1_input  | 
Measured input voltage  | 
in1_max  | 
Maximum input voltage  | 
in1_max_alarm  | 
Input voltage high alarm  | 
in1_min  | 
Minimum input voltage  | 
in1_min_alarm  | 
Input voltage low alarm  | 
in2_label  | 
“vout1”  | 
in2_input  | 
Measured output voltage  | 
in2_max  | 
Maximum output voltage  | 
in2_max_alarm  | 
Output voltage high alarm  | 
in2_min  | 
Maximum output voltage  | 
in2_min_alarm  | 
Output voltage low alarm  | 
power1_label  | 
“pin”  | 
power1_input  | 
Measured input power  | 
power1_alarm  | 
Input power alarm  | 
power1_max  | 
Maximum input power  | 
power2_label  | 
“pout1”  | 
power2_input  | 
Measured output power  | 
power2_max  | 
Maximum output power  | 
power2_max_alarm  | 
Output power high alarm  | 
temp1_input  | 
Measured temperature around input connector  | 
temp1_alarm  | 
Temperature alarm  | 
temp2_input  | 
Measured temperature around output connector  | 
temp2_alarm  | 
Temperature alarm  |